Assignment:
Largest number of fires accounts for class A fires with lots of smoke and toxic gases. As a result, smoke from burning areas must be an integral part of both fire fighting and rescue operations. smoke is removed quickly and efficiently by forcing clean air through turbogenerators.
Fans equipped with a nozzle supply of water mist to create a water mist to lower temperature in room. Water supply is via a manual ball valve on GM-50.
Key benefits:
- reduces risk of spread of fire;
- reduced amount of fire extinguishing;
- and greatly facilitated conduct of rescue operations;
- increases efficiency of evacuation of victims;
- increases safety of firefighters;
- reduced damage.
Petrol combustion engines HONDA certified according to requirements of Normative documents and have warranty cards, operating on territory of Russia.
Basic specifications:
Model | PH-VP450 | PH-VP600 | Foam adapter to PH-VP450 |
FAN | |||
Max. flow, m3/h | 38 000 | 55 000 | - |
turbine Diameter, cm | 45 | 52 | - |
vapor | - | ||
foam capacity, l/min | - | - | 180-260 |
operating pressure of solution S at inlet to foam adapter, MPa | - | - | 0,4-1,0 |
Dimensions cm | 57х55х44 | 65х62х45 | 23х63х53 |
Weight, kg | 37 | 49 | 7 |
ENGINE | HONDA GX200 | HONDA GX270 | - |
Max. powerful., kW | 5.5 | 8.5 | - |
Fuel | A95 | A95 | - |
hours, minutes | 90 | 110 | - |
For turbo fan model PH-VP450 available to order foam adapter for formation of air-mechanical foam of high expansion.